Review




Structured Review

ThermoAnalytics Inc thermoregulation model taitherm v 11.2
Thermoregulation Model Taitherm V 11.2, supplied by ThermoAnalytics Inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/thermoregulation+model+taitherm+v+11%2E2/thermoregulation+model+taitherm+v+11+2/10__1016_slash_j__buildenv__2018__03__050-143-309-312
Average 90 stars, based on 1 article reviews
thermoregulation model taitherm v 11.2 - by Bioz Stars, 2026-11
90/100 stars

Images

Related Articles

Activity Assay:

Article Title: Human simulator – A tool for predicting thermal sensation in the built environment
Article Snippet: .. No. 1 2 3 4 5 Type Steady-state Steady-state Tair ramp Tair step- change Tair step- change Duration (hours) 9 8 9 9 8 Environmental parameters Tair (°C) 28 21.5 17/25 26/30 30/26 Trad (°C) Tair 1 Tair Tair Tair 1 Tair 1 RH (%) 60 43 43 60 60 vair (m/s) 0.2 1 0.19 0.19 0.2 1 0.2 1 Subjects Number (M/F) 10/0 8/0 2 8/0 10/0 10/0 Personal parameters Activity (met) 1.2 3 1.2 1.2 1.2 3 1.1 3 Icl (clo) 0.1 0.9 0.9 0.1 0.1 M AN US CR IP T AC CE PT ED 18 Ret (m 2 Pa/W) 5 22 22 5 5 Measurement type Tcore (type) rectal rectal rectal rectal rectal mTsk (no. of points) 7 14 14 7 7 Thermal sensation votes Scale (type) - continuous continuous - - (no. of points) 7 7 7 7 7 Votes (votes per person) 20 17 17 20 20 Source of data Kakitsuba and White [56] Schellen et al. [55] Schellen et al. [55] Kakitsuba and White [56] Kakitsuba and White [56] Tair – air temperature, Trad – mean radiant temperature, RH – relative humidity, vair – air velocity, Icl, clothing thermal insulation, Ret – clothing evaporative resistance, Tcore – core temperature, mTsk – mean skin temperature, TS – thermal sensation, M/F – male/female subjects 1 Assumed values of Trad and vair (not reported in the reference) 2 Tcore and mTsk values were reported for all eight subjects, whereas thermal sensation votes were reported only for one subject 3 Average metabolic heat production calculated as the average from four 1-hour measurement periods The Rct and Ret values have been selected based on the description of the experiments and typical values from the literature [57,58] and they include both clothing ensemble and chair In a first step, the exposures were simulated with the thermoregulation model alone (Taitherm v 11.2, Thermoanalytics, US) to determine the initial surface temperature set-points for the manikin. ..

Insulation:

Article Title: Human simulator – A tool for predicting thermal sensation in the built environment
Article Snippet: .. No. 1 2 3 4 5 Type Steady-state Steady-state Tair ramp Tair step- change Tair step- change Duration (hours) 9 8 9 9 8 Environmental parameters Tair (°C) 28 21.5 17/25 26/30 30/26 Trad (°C) Tair 1 Tair Tair Tair 1 Tair 1 RH (%) 60 43 43 60 60 vair (m/s) 0.2 1 0.19 0.19 0.2 1 0.2 1 Subjects Number (M/F) 10/0 8/0 2 8/0 10/0 10/0 Personal parameters Activity (met) 1.2 3 1.2 1.2 1.2 3 1.1 3 Icl (clo) 0.1 0.9 0.9 0.1 0.1 M AN US CR IP T AC CE PT ED 18 Ret (m 2 Pa/W) 5 22 22 5 5 Measurement type Tcore (type) rectal rectal rectal rectal rectal mTsk (no. of points) 7 14 14 7 7 Thermal sensation votes Scale (type) - continuous continuous - - (no. of points) 7 7 7 7 7 Votes (votes per person) 20 17 17 20 20 Source of data Kakitsuba and White [56] Schellen et al. [55] Schellen et al. [55] Kakitsuba and White [56] Kakitsuba and White [56] Tair – air temperature, Trad – mean radiant temperature, RH – relative humidity, vair – air velocity, Icl, clothing thermal insulation, Ret – clothing evaporative resistance, Tcore – core temperature, mTsk – mean skin temperature, TS – thermal sensation, M/F – male/female subjects 1 Assumed values of Trad and vair (not reported in the reference) 2 Tcore and mTsk values were reported for all eight subjects, whereas thermal sensation votes were reported only for one subject 3 Average metabolic heat production calculated as the average from four 1-hour measurement periods The Rct and Ret values have been selected based on the description of the experiments and typical values from the literature [57,58] and they include both clothing ensemble and chair In a first step, the exposures were simulated with the thermoregulation model alone (Taitherm v 11.2, Thermoanalytics, US) to determine the initial surface temperature set-points for the manikin. ..



Similar Products

90
ThermoAnalytics Inc thermoregulation model taitherm v 11.2
Thermoregulation Model Taitherm V 11.2, supplied by ThermoAnalytics Inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/thermoregulation+model+taitherm+v+11%2E2/thermoregulation+model+taitherm+v+11+2/10__1016_slash_j__buildenv__2018__03__050-143-309-312
Average 90 stars, based on 1 article reviews
thermoregulation model taitherm v 11.2 - by Bioz Stars, 2026-11
90/100 stars
  Buy from Supplier

Image Search Results